MEDIUM VOLTAGE VACUUM CONTACTORS & STARTERS  

 
 

 

Vacuum Contactors & Starter Ratings

 

 

Description

200A

400A

600A

1200A

Catalog Number & Rated Voltage

2.5KV

VC88/3/200/2500

VC88/3/400/2500

VC88/3/600/2500

SVC88U031225

5.0KV

VC88/3/200/5000

VC88/3/400/5000

VC88/3/600/5000

SVC88U031250

7.2KV

VC88/3/200/7200

VC88/3/400/7200

VC88/3/600/7200

SVC88U031272

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum contactors power Ratings

Operational Rated Current

200A

400A

600A

800A/1200A

Operational Rated Frequency

50/60Hz

50/60Hz

50/60Hz

50/60Hz

E1 Interrupt Rating

2.5 KV

20 MVA Equivalent to 4.62 KA

-------

MVA & KA Value

5.0 KV

40 MVA Equivalent to 4.62 KA

-------

Contactor Only

7.2 KV

60 MVA Equivalent to 4.81 KA

-------

E2 Fuse Co-ordination Rating

400 MVA 45.7 KA RMS

-------

MVA & KA

5.0 KV

38 R max. fuse size

Withstand KA

5.0 KV

57.8 KA -Peak38 R -Fuse

-------

Short Time Current

1Sec. KA

6

7

9

12

5Sec. KA

4

5

6

9

15Sec .KA

2

2.6

3

6

Switching Frequency

300/Hr

Elec. Life at Rated Current

.6×106

.40×106

.250×106

.250×106

Mechanical Life

.75×106

Dielectric Strength

20KV 1min

Impluse withstand B.I.L

1.2×50us

60KV

Chopping Current Max.

.9A

 

Control Ratings AC&DC

Rated Control Voltage

120/240V 50/60Hz AC

125/250VDC

Allowable Fluctuation

+10-15%

+10-20%

Closing Power VA/Duration

650 VA/45 MS

1300 VA/45 MS

Holding Power

7 VA AC .47A DC

14 VA AC .924A DC

Opening time Ave.

90 MS at 60Hz

Closing time Ave.

40 MS at 60Hz

Pick up Voltage

Min.

102 V or less

Drop Out Voltage

Ave.

70% or less

Recommended Control Trans.

(AC Only)

300 VA

 

600VA

Application Conditions

Standard Auxiliary Contact Ratings

Current

Continuous AC/DC 10A/5A

Voltage

600V Max.-48V Min. NEMA A600 (AC) P600 (DC)

AC

Make/Break 7200VA/720 VA

DC

Make/Break 125/250 V 138VA 300/600V 138VA

Additional Auxiliary Contact Relay Ratings

Current

Continuous AC/DC 10A/2.5A

Voltage

600V Max.-48V Min. NEMA A600 (AC) Q300 (DC)

AC

Make/Break 7200VA/720VA

DC

Make/Break 125/250V/69VA

Weight

 

48 lbs.

96 lbs.

 

 

 

 

 

 

 

 

 

Voltage KV

 

2.5

3.3

4.16

6.6

Motor Type

Current

Motor HP

.8 P.F.Ind. Or Syn Motor

200A

900

1250

1500

2500

1.0 P.F.Syn Motor

200A

1000

1500

1750

2750

.8 P.F.Ind. Or Syn Motor

400A

1750

2250

3000

5000

1.0 P.F.Syn Motor

400A

2000

2500

3500

2520

.8 P.F.Ind. Or Syn Motor

600A

2250

3250

4500

6750

1.0 P.F.Syn Motor

600A

2250

3500

4750

7000

.8 P.F.Ind. Or Syn Motor

800A

2750

4000

5500

8000

Transformer Load KVA

Three Phase Transformer

200A

750

1000

1500

2000

400A

1500

2000

3000

4000

600A

2500

3000

4250

6000

800A

2750

3750

5250

7500

1200A

4100

5000

7000

10000

 

 

 

Capacitor Load KVAR

Three Phase Capacitor

200A

550

750

1050

1500

400A

1125

1500

2250

3000

600A

1650

2250

3375

4500

800A

2200

2900

4500

5000

1200A

2750

3750

5625

7500

 

 

 

 

 

Ampere Rating

Maximum Horsepower Ratings

Open Type

(A)

.8pf Ind. Or Syn. Motor

1.0pf Syn. Motor

Catalog No.

2500Volts

 

 

 

200

900

1000

VC88/3/200/2500

400

1750

2000

VC88/3/400/2500

600

2250

2500

VC88/3/600/2500

800

2750

-----

SVC88U038A25

1200

-----

-----

SVC88U031225

4160Volts

 

 

 

200

1500

1750

VC88/3/200/5000

400

3000

3500

VC88/3/400/5000

600

4500

4750

VC88/3/600/5000

800

5500

-----

SVC88U038A50

1200

-----

-----

SVC88U031250

6600Volts

 

 

 

200

2500

2750

VC88/3/200/7200

400

5000

5250

VC88/3/400/7200

600

6750

7000

VC88/3/600/7200

800

8000

-----

SVC88U038A72

1200

-----

-----

SVC88U031272

 

 

Coil Table

Voltage AC

Suffix

Voltage DC

Suffix

120

-76

125

-125

240

-26

250

-250

 

 

                                                                                                                                                                                                                      CONTROL DIAGRAM

 

     

 

 

 

CIRCUIT ASSEMBLY 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

MEDIUM VOLTAGE VACUUM CONTACTORS

 

    

 

Vacuum Contactor & Starter Ratings 1.5KV & 3.6KV

 

 

 

80/60V

160A

320A

600A

1000A

3 Pole

1.5KV

VC88/3/160/1500

VC88/3/320/1500

VC88/3/600/1500

VC88/3/1000/1500

3.6KV

VC88/3/160/3600

VC88/3/320/3600

VC88/3/600/3600

VC88/3/1000/3600

                          正面图                    侧面图

        

Vacuum Contactor Power Ratings

 

Rated Insulating And Operational Voltage

1500/3600

 

Rated Operational Current

160

320

600

1000

 

Rated Frequency

50/400Hz

 

Making Current

1600

3200

6000

6000

 

Breaking Current

1600

3200

6000

6000

 

Dielectric Strength/BIL

6KV-1 min. /45KV. 1.2×50 Micro/Sec.

 

Interrupting Current

4400

5000

6000

6000

 

Withstand Current

30KA-3Hz

 

Short Time Current

1Sec.

5000

7000

9000

11000

 

2Sec.

3000

5000

7000

9000

 

Mechanical Life

2×106

 

Electrical Life At Rated Current – AC3 Duty

1×106

 

Switching Frequency

1200/hr

 

Chop Current

Min.

.55A

 

Max.

.9A

 

Vacuum Contactor Control Ratings

 

Description

160/320A

600A

1000A

 

Rated Control Voltage

120/240V 50/400Hz

 

Allowable Fluctuation

+10% of rated -25%voltage

Closing Power VA/Duration

950VA/17MS

1900VA/17MS

2850VA/17MS

Holding Power

9VA

18VA

27VA

Opening Time Ave.

90MS at 60Hz

Closing Time Ave.

17MS at 60Hz

Picking Up Voltage

90V

Drop Out Voltage

70℅or less

Recommended Control Transformer

When Required 250VA

When Required 500VA

When Required 750VA

Vacuum Contactor Application Conditions

Installation

All planes up to 6600 ft.(2000m)

Ambient

Storage

-65℉(-54)+160℉(71)

Operating

-40℉(-40)+135℉(67)

Vibration/Shock

40Hz-2G/30G

Weight 160/320A

12lbs.(5.45kg)

24lbs.(11kg)

36lbs,(16.36kg)

Dimensions (mm)

225×189×200

450×189×200

676×189×200

                 

 

 

Motor HP

 

Volts

160A

320A

600A

1000A

230

60

125

200

-----

460

125

250

500

-----

1000

300

600

1200

-----

1500

420

850

1600

-----

2300

600

1250

2400

-----

3300

960

1920

3700

-----

Transformer Load (KVA) 

 

Volts

160A

320A

600A

1000A

230

66

133

250

415

460

127

255

500

746

1000

277

554

1000

1730

1500

415

850

1500

2600

2300

665

1330

2500

4150

3300

910

1820

3400

5700

Capacitor Load(KVAR) 

 

Volts

160A

320A

600A

1000A

230

50

100

180

310

460

95

190

360

595

1000

205

415

750

1300

1500

310

620

1125

1450

2300

500

1000

1875

3110

3300

700

1365

2550

4275

 

 

 

Coil Table

Voltage AC

Suffix

Voltage DC

Suffix

120

-76

125

-125

240

-26

250

-250

 

 

 

 

 

 

 

 

       

 

 

 

 

 

 

 

 